Home
Download PDF
Order CD-ROM
Order in Print
Home
>
USACE Technical Letters - index
>
> Appendix G: Non-Series-Parallel System Analysis cont'd
Appendix G: Non-Series-Parallel System Analysis
ETL 1110-2-560
ETL 1110-2-560
Page Navigation
44
45
46
47
48
49
50
ETL
1110-2-560
30
Jun
01
Figure
G-3
is
resolved
as
R
S
(if
A
fails)
= 1 -
({1
[R
B1
(t)
* R
C1
(t)]}
{1 [R
B2
(t)
* R
C2
(t)]})
(G-3)
The
total
system
reliability
becomes
R
S
(t)
= R
S
(if
A is
working)
R
A
(t)
+ R
S
(if
A
fails)
[1 - R
A
(t)]
(G-4)
G-2