ETL 1110-2-365
31 Aug 94
the behavior of the structure. These plots should
should explain any cracking or the potential for
include temperature, stress and crack potential con-
cracking, whether it is acceptable, what special design
tours at critical times, plus temperature and stress
or construction procedure changes might be required,
time histories at critical locations. There should also
and what cost adjustment was made because of these
be a narrative interpretation of the results. This
changes.
A1-2