l. Geosynthetic Clay Liner.
Will a GCL be used at this site?
Y__N__N/A__
Will regulators allow the use of a GCL at this site?
Y__N__N/A__
m. Gas Collection and Removal System .
Is a gas collection and removal system applicable at this site?
Y__N__N/A__
Have analyses been performed to determine the landfill gas
types and emission rates?
Y__N__N/A__
Do vertical or lateral migration routes or barriers exist?
Y__N__N/A__
Have the state requirements for gas control and treatment
been determined?
Y__N__N/A__
Are there nearby residences or structures (within 300 m
[1000 ft]) that could be adversely impacted by migration
of landfill gases?
Y__N__N/A__
Are gas monitoring probes needed between the landfill and
structures?
Y__N__N/A__
Is an active gas control system needed owing to the
volume of gas being generated?
Y__N__N/A__
Is a gas collection well system most appropriate for this site?
Y__N__N/A__
Is a gas collection trench system most appropriate
for this site?
Y__N__N/A__
Is a gas collection blanket system most appropriate
for this site?
Y__N__N/A__
Is a perimeter collection trench needed?
Y__N__N/A__
If a geosynthetic gas collection layer is used, does it have
adequate flow capacity?
Y__N__N/A__